B
84

US Water Score: B

Saint Georges, DE 19733

New Castle County · Population served: 100,495 · Data updated July 2026

Service-area evidence: EPA service-area records associate the listed system with this ZIP. Boundaries may still overlap or change.

Water Systems Serving This Area

🏔
VEOLIA WATER DELAWARE, INC
Surface water · Pop. 100,495
PWSID: DE0000564

Contaminants Detected

ContaminantDetected LevelEPA MCLHealth GuidelineStatus
Lead
2.0
15 ppb 1 ppb Warning

PFAS / Forever Chemicals

9 detected 2 above comparison value

UCMR5 occurrence results are screening information, not a finding of regulatory compliance or noncompliance. PFAS rules and compliance dates are evolving.

CompoundLevelEPA MCLHealth GuidelineStatus
PFBA40.6 pptNo standard500 pptNo federal MCL shown
PFPeA32.1 pptNo standardNo federal MCL shown
PFHxA31.7 pptNo standard400 pptNo federal MCL shown
PFHpA27.7 pptNo standardNo federal MCL shown
PFOA24.4 ppt4 ppt4 pptAbove comparison value
PFNA11.6 ppt10 ppt10 pptAbove comparison value
PFDA4.7 pptNo standardNo federal MCL shown
PFUnA3.8 pptNo standardNo federal MCL shown

Water Quality Summary

Understanding Your Water in Saint Georges

Tap water quality in Saint Georges, Delaware (19733) receives an overall grade of B (Moderate-low record-based concern) with a score of 84 out of 100, based on analysis of EPA compliance data, contaminant testing, and violation history. This is roughly in line with the Delaware state average of 84. The area is served by Veolia Water Delaware, Inc, a surface water system providing water to approximately 100,495 people. Testing has found elevated levels of Lead that warrant attention. Notably, 2 PFAS compounds exceed the EPA final MCL value used for comparison — a significant concern given the persistent nature of these chemicals. The area has a clean violation record over the past 5 years — a positive indicator of consistent water quality management.

Your Score 84/100 B
vs State 0 pts above Delaware avg (84)
vs National 9 pts above national avg (75)

What a Grade B Means

A score of 84/100 means Saint Georges, DE performs well in the US Water Score model, with only minor system-level concerns. Residents should still review their utility's Consumer Confidence Report for official compliance information and household-specific context.

Surface water: sourced from rivers, lakes, or reservoirs

Health Information

What These Contaminants Mean for You

⚠️

Lead in Your Water

Lead is a toxic metal that can leach from aging pipes and plumbing fixtures.

Health Effects

Even low levels of lead exposure can cause developmental delays in children, kidney damage, and cardiovascular effects in adults. The EPA action level is 15 ppb, but health experts recommend no safe level of lead in drinking water.

Common Sources

Lead enters water primarily through corrosion of lead service lines, lead solder, and brass fixtures — especially in homes built before 1986.

What You Can Do

If lead is detected above 1 ppb, consider using a certified lead-removal filter (NSF/ANSI 53) for drinking and cooking water. Run cold water for 30 seconds before use if water has been sitting in pipes.

Common Questions

Frequently Asked Questions

Based on public water-system records, Saint Georges, Delaware receives an internal US Water Score grade of B (Moderate-low record-based concern) with a score of 84/100. This indicates relatively few system-level concerns in our model, but it is not an EPA safety rating and does not guarantee tap conditions inside individual homes.

ZIP code 19733 is served by 1 water system using surface water sources, providing water to approximately 100,495 people. Surface water systems are more susceptible to contamination from agricultural runoff, industrial discharge, and weather events, but typically undergo more extensive treatment including filtration and disinfection.

Lead was reported at 2.0 ppb in public-system records for Saint Georges, Delaware. This is below the currently applicable EPA action level of 15 ppb, but may be above more protective health guidance; EPA's future LCRI action level is 10 ppb. Household plumbing can materially change tap-level exposure, so consider certified filtration and individual tap testing, especially where children are present.

Yes — 9 PFAS compounds were detected in records associated with water serving Saint Georges, Delaware, and 2 results exceeded the numerical EPA MCL value used for comparison. UCMR5 occurrence results alone are not a regulatory compliance determination. PFAS rules and compliance timelines are evolving; verify current information with the utility and EPA.

Water systems serving Saint Georges, Delaware have zero violations in the last 5 years. This is a positive indicator of consistent regulatory compliance and water quality management.

Based on detected contaminants (lead, PFAS), residents in Saint Georges, Delaware should consider: Reverse osmosis (RO) system — most effective for PFAS, lead, and other contaminants. Always look for filters with NSF/ANSI certification for the specific contaminants you want to remove.