B
79

Record-only indicator: B

Not a safety rating. Missing or old measurements can produce a high score.

Coverage: 9/10 mapped systems have a dated lead result; 1/10 have copper results; 3/10 have UCMR monitoring.

Dallas, PA 18612

Luzerne County · Population served: 11,987 · SDWIS 2026-07-21 · UCMR5 August 2026

Service-area evidence: EPA service-area records associate the listed system with this ZIP. Boundaries may still overlap or change.

Water Systems Serving This Area

🏔
PAW HUNTSVILLE
Surface water · Pop. 11,987

Lead: 1.8 ppb; period end 09/30/2025. Copper: not available ppb; period end unknown.

PWSID: PA2409013
🌊
VEOLIA WATER PA DALLAS
Groundwater · Pop. 7,563

Lead: 3.4 ppb; period end 09/30/2025. Copper: not available ppb; period end unknown.

PWSID: PA2400076
🏔
SCI DALLAS
Surface water · Pop. 2,900

Lead: 5.0 ppb; period end 12/31/1996. Copper: not available ppb; period end unknown.

PWSID: PA2400090
🌊
EEI MEADOWS COMPLEX
Groundwater · Pop. 628

Lead: 672.25 ppb; period end 09/30/2019. Copper: not available ppb; period end unknown.

PWSID: PA2400115
🌊
COUNTRY VILLAGE MHP
Groundwater · Pop. 175

Lead: 5.0 ppb; period end 12/31/1996. Copper: not available ppb; period end unknown.

PWSID: PA2400041

Reported lead and copper results

ContaminantReported value or boundHistorical comparison valueInterpretationStatus
Lead
672.25 ppbPeriod end: 09/30/2019
15 ppb Largest reported value or bound among mapped systems; not necessarily the largest actual concentration. Above comparison value
Copper
2900.0 ppbPeriod end: 09/30/2025
1300 ppb Largest reported value or bound among mapped systems; not necessarily the largest actual concentration. Above comparison value

PFAS / Forever Chemicals

6 detected 2 above comparison value

UCMR5 occurrence results are screening information, not a finding of regulatory compliance or noncompliance. PFAS rules and compliance dates are evolving.

CompoundLevelEPA MCLInterpretationStatus
PFOS7.9 ppt4 ppt4 pptAbove comparison value
PFPeA4.3 pptNo standard—No federal MCL shown
PFOA4.1 ppt4 ppt4 pptAbove comparison value
PFBS3.9 pptNo standard100 pptNo federal MCL shown
PFHxA3.5 pptNo standard400 pptNo federal MCL shown
PFHxS3.5 ppt10 ppt10 pptBelow comparison value

Violation History (Last 5 Years)

285Total (5yr)
3Health-Based
193Major

Public-record summary

Understanding Your Water in Dallas

Record-only indicator — incomplete or old records can produce a high score. A score of 100 is not a safety finding. Coverage: 9/10 mapped systems have a dated lead result; 1/10 have copper results; 3/10 have UCMR monitoring. Tap water quality in Dallas, Pennsylvania (18612) receives an record-only indicator of B (Moderate-low record-based concern) with a score of 79 out of 100, based on analysis of EPA compliance data, contaminant testing, and violation history. This is 15 points above the Pennsylvania state average of 64. The area is served by 10 water systems providing water to approximately 11,987 people, using surface water and groundwater sources. Testing has found elevated levels of Lead, Copper that warrant attention. Notably, 2 PFAS compounds exceed the EPA final MCL value used for comparison — a significant concern given the persistent nature of these chemicals. Over the past 5 years, water systems here have accumulated 285 violations, including 3 health-based violations.

Record-only score 79/100 B
vs State ▲ 15 pts above Pennsylvania avg (64)
Comparison limits No national safety ranking: coverage and service areas overlap.

What a Grade B Means

Grade B summarizes the records available to this model, not household safety. Missing, bounded or old measurements can produce a high score, including 100. Review coverage, dates and the current utility report before interpreting this indicator.

Surface water: sourced from rivers, lakes, or reservoirs
Groundwater: drawn from underground aquifers via wells

Health Information

What These Contaminants Mean for You

⚠️

Lead in Your Water

Lead is a toxic metal that can leach from aging pipes and plumbing fixtures.

Health Effects

Even low levels of lead exposure can cause developmental delays in children, kidney damage, and cardiovascular effects in adults. The EPA action level is 15 ppb, but health experts recommend no safe level of lead in drinking water.

Common Sources

Lead enters water primarily through corrosion of lead service lines, lead solder, and brass fixtures — especially in homes built before 1986.

What You Can Do

If lead is detected above 1 ppb, consider using a certified lead-removal filter (NSF/ANSI 53) for drinking and cooking water. Run cold water for 30 seconds before use if water has been sitting in pipes.

🔶

Copper in Your Water

Copper can leach into water from copper plumbing, especially in newer homes or when water is acidic.

Health Effects

Short-term exposure above 1,300 ppb can cause gastrointestinal distress. Long-term exposure may cause liver or kidney damage. People with Wilson's disease are especially vulnerable.

Common Sources

Copper pipes, fittings, and faucets are the most common source. Corrosive (low-pH) water accelerates copper leaching.

What You Can Do

If copper levels are elevated, flush pipes by running water for 15–30 seconds before use. Reverse osmosis and distillation systems effectively remove copper.

Common Questions

Frequently Asked Questions

The record-only indicator is B (79/100). It cannot determine whether your tap water is safe. Missing, bounded or old measurements can produce a high score. Check the coverage and sampling dates below and your utility's current notices.

ZIP code 18612 is served by 10 water systems using surface water, groundwater sources, providing water to approximately 11,987 people. Multiple source types mean your water may come from a blend of surface and underground sources.

The largest reported lead value or bound is 672.25 ppb, for the sampling period ending 09/30/2019. This is a system-level 90th-percentile record, not a measurement at your tap. Compare the sampling date and original utility report before interpreting it.

Yes — 6 PFAS compounds were detected in records associated with water serving Dallas, Pennsylvania, and 2 results exceeded the numerical EPA MCL value used for comparison. UCMR5 occurrence results alone are not a regulatory compliance determination. PFAS rules and compliance timelines are evolving; verify current information with the utility and EPA.

Water systems serving Dallas, Pennsylvania have received 285 violations in the last 5 years, including 3 health-based violations. Violations can range from paperwork issues (monitoring & reporting) to serious health-based violations where contaminant levels exceeded safe limits. Review the violation details above for specifics.

This public-record indicator cannot select household treatment. Confirm your supplier, current utility report and tap-testing results first; match any treatment to a certified contaminant-reduction claim and follow its maintenance instructions.

Explore Nearby

Water Quality in Nearby ZIP Codes